No part of this document may be reproduced in any form without the written permission of the copyright owner. The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document.
Trademark List
SmartEdge | is a registered trademark of Telefonaktiebolaget L M Ericsson. | |
NetOp | is a trademark of Telefonaktiebolaget L M Ericsson. |
This document describes alarm conditions and their probable causes in the SmartEdge chassis and in controller cards, carrier cards, traffic cards, media interface cards (MICs), and their ports.
The term controller carrier card refers to the controller functions on the circuit board within the SmartEdge 100 chassis; these functions are compatible with the XCRP3 Controller card. The term I/O carrier card refers to the traffic card functions on the circuit board; these functions are compatible with the similar functions that are implemented on all SmartEdge 400 and SmartEdge 800 traffic cards.
The term replaceable unit is a generic description of a component (fan, power supply, controller card, controller carrier card, I/O carrier card, and others) with an alarm that cannot be resolved for the current unit. Because only SmartEdge 100 MICs and small form-factor plug-capable (SFP) transceivers are replaceable in a SmartEdge 100 chassis, the resolution of an alarm for any other SmartEdge 100 component requires that you replace the SmartEdge 100 chassis.
Table 1 lists supported alarms for the SmartEdge 100 chassis and system as a whole.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
Chassis power failure—Side A |
Minor |
PowerProblem |
No |
Fan unit failure |
Minor |
CoolingFanFailure |
No |
Local alarm cutoff activated |
Minor |
OperationNotification |
No |
Multiple fan failure |
Major |
ReplaceableUnitProblem |
Yes |
Power supply output fail |
Minor |
ReplaceableUnitProblem |
Yes |
Remote alarm cutoff activated |
Minor |
OperationNotification |
No |
Table 2 lists supported alarms for all other SmartEdge chassis and systems as a whole.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
Chassis power capacity exceeded |
Major |
MisMatchedControllerCard |
Yes |
AC power failure—side A |
Minor |
ReplaceableUnitProblem |
No |
AC power failure—side B |
Minor |
ReplaceableUnitProblem |
No |
AC power missing—side A |
Minor |
ReplaceableUnitMissing |
No |
AC power missing—side B |
Minor |
ReplaceableUnitMissing |
No |
Chassis power failure—Side A1 |
Minor |
PowerProblem |
No |
Chassis power failure—Side A2 |
Minor |
PowerProblem |
No |
Chassis power failure—Side B1 |
Minor |
PowerProblem |
No |
Chassis power failure—Side B2 |
Minor |
PowerProblem |
No |
AC power overheat—side A |
Minor |
ReplaceableUnitProblem |
No |
AC power overheat—side B |
Minor |
ReplaceableUnitProblem |
No |
Alarm card missing |
Major |
ReplaceableUnitMissing |
Yes |
Chassis power failure—side A |
Minor |
PowerProblem |
No |
Chassis power failure—side B |
Minor |
PowerProblem |
No |
Fan tray comm failure—side A |
Minor |
CoolingFanFailure |
No |
Fan tray comm failure—side B |
Minor |
CoolingFanFailure |
No |
Fan tray communication failure |
Major |
CoolingFanFailure |
Yes |
Fan tray controller (card) failure |
Major |
ReplaceableUnitProblem |
Yes |
Fan tray controller (card) overheat |
Major |
ReplaceableUnitProblem |
Yes |
Fan tray failure detected |
Minor |
ReplaceableUnitProblem |
No |
Fan tray filter replacement |
Major |
ReplaceableUnitProblem |
Yes |
Fan tray fuse failure |
Major |
ReplaceableUnitProblem |
Yes |
Fan tray missing |
Major |
ReplaceableUnitMissing |
Yes |
Fan tray reset occurred |
Warning |
Reinitialized |
Yes |
Fan unit failure |
Minor |
CoolingFanFailure |
No |
Local alarm cutoff activated |
Minor |
OperationNotification |
No |
Mesh diagnostic failure |
Major |
ReplaceableUnitFailure |
Yes |
Multiple fan failure |
Major |
ReplaceableUnitProblem |
Yes |
Remote alarm cutoff activated |
Minor |
OperationNotification |
No |
Table 3 lists the supported alarms for the SmartEdge 100 controller carrier card.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
Controller (card) code mismatch |
Major |
ReplaceableUnitTypeMismatch |
Yes |
Controller (card) fail |
Critical |
ReplaceableUnitProblem |
Yes |
Controller (card) overheating |
Major |
ReplaceableUnitProblem |
Yes |
Controller (card) power-on diagnostic failed |
Major |
ReplaceableUnitProblem |
Yes |
Controller (card) temperature critical |
Major |
ReplaceableUnitProblem |
Yes |
Diagnostic test fail |
Major |
ReplaceableUnitProblem |
Yes |
Local inventory fail |
Major |
ReplaceableUnitProblem |
Yes |
Nonvolatile memory fail |
Major |
CorruptData |
Yes |
Real-time clock failure |
Major |
RealTimeClockFailure |
Yes |
Table 4 lists the supported alarms for XCRP and XCRP3, and XCRP4 controller cards.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
Backup fail: peer dead (1) |
Major |
ReplaceableUnitProblem |
Yes |
Controller (card) auto switch completed |
Major |
OperationNotification |
Yes |
Controller (card) code mismatch |
Major |
ReplaceableUnitTypeMismatch |
Yes |
Controller (card) exerciser switch failed |
Major |
OperationFailure |
Yes |
Controller (card) fail |
Critical |
ReplaceableUnitProblem |
Yes |
Controller (card) forced switch requested |
Major |
OperationNotification |
Yes |
Controller (card) manual switch requested |
Major |
OperationNotification |
Yes |
Controller (card) missing |
Critical |
ReplaceableUnitMissing |
Yes |
Controller (card) overheating |
Major |
ReplaceableUnitProblem |
Yes |
Controller (card) power-on diagnostic failed |
Major |
ReplaceableUnitProblem |
Yes |
Controller (card) switch completed |
Major |
OperationNotification |
Yes |
Controller (card) switch failed |
Major |
OperationFailure |
Yes |
Controller (card) temperature critical |
Major |
ReplaceableUnitProblem |
Yes |
Controller (card) temperature hot |
Minor |
ReplaceableUnitProblem |
Yes |
Controller (card) type mismatch |
Major |
ReplaceableUnitTypeMismatch |
Yes |
Diagnostic test fail |
Major |
ReplaceableUnitProblem |
Yes |
Local backplane inventory fail |
Major |
ReplaceableUnitProblem |
Yes |
Local fan tray inventory fail |
Major |
ReplaceableUnitProblem |
Yes |
Local inventory fail |
Major |
ReplaceableUnitProblem |
Yes |
Nonvolatile memory fail |
Major |
CorruptData |
Yes |
Peer controller card type incompatible |
Major |
ReplaceableUnitProblem |
Yes |
Peer inventory fail |
Major |
ReplaceableUnitProblem |
Yes |
Peer shared format mismatch |
Major |
ReplaceableUnitProblem |
Yes |
Peer Sonet/Sdh mode incompatible |
Major |
ReplaceableUnitProblem |
Yes |
Real-time clock failure |
Major |
RealTimeClockFailure |
Yes |
Redundancy link fail |
Major |
OperationFail |
Yes |
(1) This alarm is suppressed
if the system has a single controller card and has been configured
using the system alarm command (in global configuration
mode) with the redundancy suppress construct.
Table 5 lists the supported alarms for the SmartEdge 100 I/O carrier card (which provides traffic card functions). In this table, the term circuit pack refers to any traffic card, MIC, or I/O carrier card.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
Circuit pack card code mismatch |
Minor |
ReplaceableUnitTypeMismatch |
No |
Circuit pack failure |
Critical |
ReplaceableUnitProblem |
Yes |
Circuit pack mismatch |
Critical |
ReplaceableUnitTypeMismatch |
Yes |
Circuit pack missing |
Critical |
ReplaceableUnitMissing |
Yes |
Circuit pack overheating |
Major |
LineCardProblem |
Yes |
Circuit pack power-on diagnostic failed |
Major |
ReplaceableUnitProblem |
Yes |
Circuit pack reset completed |
Warning |
OperationNotification |
Yes |
Diagnostic fail |
Major |
ReplaceableUnitProblem |
Yes |
Software download completed |
Warning |
OperationNotification |
Yes |
Software download failed |
Warning |
OperationFailure |
Yes |
Synchronization failure |
Critical |
TimingProblem |
Yes |
Voltage failure detected |
Major |
ReplaceableUnitProblem |
Yes |
Table 6 lists the supported alarms for the SmartEdge 100 MICs. MIC-1 indicates the MIC in the first MIC slot (ports 3 to 14); MIC-2 indicates the MIC in the second MIC slot (ports 15 to 26).
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
MIC-1 diagnostic fail |
Major |
ReplaceableUnitProblem |
Yes |
MIC-1 failure |
Critical |
ReplaceableUnitProblem |
Yes |
MIC-1 MIC type mismatch |
Critical |
ReplaceableUnitTypeMismatch |
Yes |
MIC-1 missing |
Critical |
ReplaceableUnitMissing |
Yes |
MIC-1 overheat |
Major |
ReplaceableUnitProblem |
Yes |
MIC-1 power-on diagnostic failed |
Major |
ReplaceableUnitProblem |
Yes |
MIC-1 voltage failed |
Major |
ReplaceableUnitProblem |
Yes |
MIC-2 diagnostic fail |
Major |
ReplaceableUnitProblem |
Yes |
MIC-2 failure |
Critical |
ReplaceableUnitProblem |
Yes |
MIC-2 MIC type mismatch |
Critical |
ReplaceableUnitTypeMismatch |
Yes |
MIC-2 missing |
Critical |
ReplaceableUnitMissing |
Yes |
MIC-2 overheat |
Major |
ReplaceableUnitProblem |
Yes |
MIC-2 power-on diagnostic failed |
Major |
ReplaceableUnitProblem |
Yes |
MIC-2 voltage failed |
Major |
ReplaceableUnitProblem |
Yes |
Table 7 lists the supported alarms for SmartEdge traffic cards.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
Bridging Transmission Convergence (BTC) interface error detected |
Major |
ReplaceableUnitProblem |
Yes |
BTC not ready |
Major |
ReplaceableUnitProblem |
Yes |
Circuit pack backplane degrade |
Minor |
BackplaneFailure |
No |
Circuit pack backplane failure |
Major |
BackplaneFailure |
Yes |
Circuit pack card code mismatch |
Minor |
ReplaceableUnitTypeMismatch |
No |
Circuit pack failure |
Critical |
ReplaceableUnitProblem |
Yes |
Circuit pack mismatch |
Critical |
ReplaceableUnitTypeMismatch |
Yes |
Circuit pack missing |
Critical |
ReplaceableUnitMissing |
Yes |
Circuit pack overheating |
Major |
LineCardProblem |
Yes |
Circuit pack power-on diagnostic failed |
Major |
ReplaceableUnitProblem |
Yes |
Circuit pack reset completed |
Warning |
OperationNotification |
Yes |
Diagnostic fail |
Major |
ReplaceableUnitProblem |
Yes |
Loss of backplane clock |
Major |
ReplaceableUnitProblem |
Yes |
Software download completed |
Warning |
OperationNotification |
Yes |
Software download failed |
Warning |
OperationFailure |
Yes |
Synchronization failure |
Critical |
TimingProblem |
Yes |
Voltage failure detected |
Major |
ReplaceableUnitProblem |
Yes |
Faults are reported separately for SSE cards, SSE disks, SSE groups, and partitions. See Table 8, Table 9, Table 10, and Table 11 for alarm descriptions.
You can configure the threshold for low-partition-space alarms using the following command in SSE partition configuration mode:
alarm low-partition-space raise-at raise_percentage clear-at clear_percentage
Verify card- and disk-level alarms using the show hardware slot detail command. Verify group- and partition-level alarms using the show sse group group_name detail command.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
SSE group partition not operational(1) |
Major |
operationFailure |
Yes |
SSE group partition sync in progress |
Minor |
operationNotification |
No |
SSE group partition data sync failed |
Major |
operationFailure |
Yes |
SSE group partition full |
Major |
operationNotification |
Yes |
SSE group partition low space |
Minor |
operationNotification |
No |
SSE group partition not operational at standby(2) |
Major |
operationFailure |
Yes |
(1) Probable causes:
a) The disk does not have enough space to create the partition; b)
Another partition of the same name but with a different size already
exists on the disk from a previous configuration. Solution: Use the delete partition command to free up disk space or remove
the existing partition, or use the format sse command
to remove all user-configured partitions on the disk. The format sse command can only be run on an SSE card that
is not bound to any SSE group.
(2) Probable
causes: a) The disk does not have enough space to create the partition;
b) Another partition of the same name but with a different size already
exists on the disk from a previous configuration. Solution: Use the delete partition command to free up disk space or remove
the existing partition, or use the format sse command
to remove all user-configured partitions on the disk. The format sse command can only be run on an SSE card that
is not bound to any SSE group.
This section provides tables of alarms for the following types of ports.
The tables in this section apply to ports on the ATM OC traffic cards and MICs and Packet over SONET/SDH (POS), channelized OC-12, and STM-1 traffic cards.
Table 12 lists the supported optical port alarms for the physical layer.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
Port facility loopback enabled |
Minor |
OperationNotification |
No |
Port terminal loopback enabled |
Minor |
OperationNotification |
No |
Receive laser failure |
Critical |
DemodulationFailure |
Yes |
Table 13 lists the supported optical port alarms for the section/regenerator section layer.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
Loss of frame |
Critical |
LossOfFrame |
Yes |
Loss of signal |
Critical |
LossOfSignal |
Yes |
Section DCC (data communications channel) link down |
Major |
ExternalIFDeviceProblem |
Yes |
Section signal degrade (BER [bit error rate]) |
Major |
DegradedSignal |
Yes |
Section signal failure (BER) |
Major |
ExcessiveBER |
Yes |
Table 14 lists the supported optical port alarms for the line/multiplex section layer.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
Line alarm indication signal (AIS-L) |
Minor |
AIS |
No |
Line DCC (data communications channel) link down |
Major |
ExternalIFDeviceProblem |
Yes |
Line remote defect indication (RDI-L) |
Minor |
FarEndReceiverFailure |
No |
Line signal degrade (BER [bit error rate]) |
Major |
DegradedSignal |
Yes |
Line signal failure (BER) |
Major |
ExcessiveBER |
Yes |
Lockout protection requested |
Major |
OperationNotification |
Yes |
Lockout working requested |
Major |
OperationNotification |
Yes |
Loss of clock |
Major |
LossOfTimingSource |
Yes |
Port auto switch completed |
Major |
OperationNotification |
Yes |
Port channel mismatch |
Major |
ApsChannelMatchFailure |
Yes |
Port diagnostic failed |
Major |
ReplaceableUnitProblem |
Yes |
Port far-end protection line failure |
Major |
ApsChannelProcessingFailure |
Yes |
Port fault oscillations detected |
Critical |
DegradedSignal |
Yes |
Port forced switch requested |
Major |
OperationNotification |
Yes |
Port manual switch request |
Major |
OperationNotification |
Yes |
Port mode mismatch |
Major |
ApsModeMismatch |
Yes |
Port protection switch byte failure |
Major |
ApsByteFailure |
Yes |
Port switch completed |
Major |
OperationNotification |
Yes |
Port switch lockout requested |
Major |
OperationNotification |
Yes |
Port payload loopback enabled |
Minor |
OperationNotification |
No |
Port switch failed |
Major |
OperationFailure |
Yes |
Port switch protection path failure |
Major |
OperationFailure |
Yes |
Port switch waiting to restore |
Minor |
OperationNotification |
No |
Severely errored frames (SEF) |
Major |
ErroredFrame |
No |
Table 15 lists the alarms and warnings supported by the SFP transceivers displayed by the show system alarm command.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
Transceiver receive power–high |
Major |
Replaceable Unit Problem |
Yes |
Transceiver receive power–low |
Major |
Replaceable Unit Problem |
Yes |
Transceiver TX power–high |
Major |
Replaceable Unit Problem |
Yes |
Transceiver TX power–low |
Major |
Replaceable Unit Problem |
Yes |
Transceiver temperature–high |
Major |
Replaceable Unit Problem |
Yes |
Transceiver temperature–low |
Major |
Replaceable Unit Problem |
Yes |
Transceiver bias current–high |
Major |
Replaceable Unit Problem |
Yes |
Transceiver bias current–low |
Major |
Replaceable Unit Problem |
Yes |
Transceiver receive power–high warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver receive power–low warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver TX power–high warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver TX power–low warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver temperature–high warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver temperature–low warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver bias current–high warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver bias current–low warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver voltage–high |
Major |
Replaceable Unit Problem |
Yes |
Transceiver voltage–low |
Major |
Replaceable Unit Problem |
Yes |
Transceiver voltage–high warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver voltage–low warning |
Minor |
Replaceable Unit Problem |
No |
Table 16 lists the alarms and warnings supported by the XFP transceivers displayed by the show system alarm command.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
Transceiver receive power–high |
Major |
Replaceable Unit Problem |
Yes |
Transceiver receive power–low |
Major |
Replaceable Unit Problem |
Yes |
Transceiver TX power–high |
Major |
Replaceable Unit Problem |
Yes |
Transceiver TX power–low |
Major |
Replaceable Unit Problem |
Yes |
Transceiver temperature–high |
Major |
Replaceable Unit Problem |
Yes |
Transceiver temperature–low |
Major |
Replaceable Unit Problem |
Yes |
Transceiver bias current–high |
Major |
Replaceable Unit Problem |
Yes |
Transceiver bias current–low |
Major |
Replaceable Unit Problem |
Yes |
Transceiver receive power–high warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver receive power–low warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver TX power–high warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver TX power–low warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver temperature–high warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver temperature–low warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver bias current–high warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver bias current–low warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver AUX1–high |
Major |
Replaceable Unit Problem |
Yes |
Transceiver AUX1–low |
Major |
Replaceable Unit Problem |
Yes |
Transceiver AUX2–high |
Major |
Replaceable Unit Problem |
Yes |
Transceiver AUX2–low |
Major |
Replaceable Unit Problem |
Yes |
Transceiver AUX1–high warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver AUX1–low warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver AUX2–high warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver AUX2–low warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver L-VCC5–high |
Major |
Replaceable Unit Problem |
Yes |
Transceiver L-VCC5–low |
Major |
Replaceable Unit Problem |
Yes |
Transceiver L-VCC3–high |
Major |
Replaceable Unit Problem |
Yes |
Transceiver L-VCC3–low |
Major |
Replaceable Unit Problem |
Yes |
Transceiver L-VCC2–high |
Major |
Replaceable Unit Problem |
Yes |
Transceiver L-VCC2–low |
Major |
Replaceable Unit Problem |
Yes |
Transceiver L-VCC5–high warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver L-VCC5–low warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver L-VCC3–high warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver L-VCC3–low warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver L-VCC2–high warning |
Minor |
Replaceable Unit Problem |
No |
Transceiver L-VCC2–low warning |
Minor |
Replaceable Unit Problem |
No |
Table 17 lists the supported alarms for ATM DS-3 ports.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
ATM add-drop multiplexer (ADM) loss of cell delineation |
Minor |
DegradedSignal |
No |
ATM PLCP (Physical Layer Convergence Protocol) loss of frame |
Minor |
LossOfFrame |
No |
ATM PLCP remote alarm indication |
Minor |
FarEndReceiverFailure |
No |
Table 18 lists the supported alarms for DS-3 channels on channelized OC-12 ports, DS-3 clear-channel and channelized ports, and clear-channel E3 ports. Not all alarms apply to all DS-3 channel or port types; the card type determines the applicable alarms.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
Bit error rate exceeded threshold |
Major |
ExcessiveBER |
Yes |
Facility loopback enabled |
Minor |
OperationNotification |
No |
Far-end alarm indication signal (AIS) |
Minor |
AIS |
No |
Far-end common equipment failure |
Minor |
ReplaceableUnitProblem |
No |
Far-end equipment failure (non-service-affecting) |
Minor |
ReplaceableUnitProblem |
No |
Far-end equipment failure (service-affecting) |
Major |
ReplaceableUnitProblem |
Yes |
Far-end idle signal |
Minor |
FarEndReceiverFailure |
No |
Far-end loss of signal |
Minor |
LossOfSignal |
No |
Far-end out of frame |
Minor |
LossOfFrame |
No |
Payload loopback enabled |
Minor |
OperationNotification |
No |
Port diagnostic failure |
Major |
ReplaceableUnitProblem |
Yes |
Receive alarm indication signal (AIS) |
Minor |
AIS |
No |
Receive Bit Interleaved Parity (BIP) violation |
Major |
ReceiveFailure |
Yes |
Receive framing mismatch |
Critical |
PayloadTypeMismatch |
Yes |
Receive frequency out of range |
Major |
ReceiveFailure |
Yes |
Receive IDLE signal |
Major |
FarEndReceiverFailure |
Yes |
Receive loss of frame (LOF) |
Critical |
LossOfFrame |
Yes |
Receive loss of signal (LOS) |
Critical |
LossOfSignal |
Yes |
Receive parity error exceeded threshold |
Major |
ExcessiveBER |
Yes |
Receive remote alarm indication (RAI) |
Minor |
FarEndReceiverFailure |
No |
Remote Line Loopback |
Minor |
OperationNotification |
No |
Transmit frequency out of range |
Major |
TransmitFailure |
Yes |
Transmit path alarm indication signal (AIS-P) |
Major |
TransmitFailure |
Yes |
Transmit path loss of pointer (LOP-P) |
Major |
LossOfPointer |
Yes |
Transmit path trace mismatch |
Major |
TransmitFailure |
Yes |
Transmit path unequipped (UNEQ-P) |
Major |
TransmitFailure |
Yes |
Transmit remote failure indication (RFI-P) |
Minor |
TransmitFailure |
No |
Transmit signal label mismatch (PLM-P) |
Major |
SignalLabelMismatch |
Yes |
Terminal loopback enabled |
Minor |
OperationNotification |
No |
Table 19 lists the supported alarms for DS-1 channels and paths.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
DS-1 packet link down |
Minor |
LinkFailure |
No |
DS-1 payload loopback enabled |
Minor |
OperationNotification |
No |
Port diagnostic failed |
Minor |
ReplaceableUnitProblem |
No |
Port facility loopback enabled |
Minor |
OperationNotification |
No |
Port terminal loopback enabled |
Minor |
OperationNotification |
No |
Receive alarm indication signal (AIS) |
Minor |
AIS |
No |
Receive loss of frame (LOF) |
Major |
LossOfFrame |
Yes |
Receive loss of multi-frame alignment |
Major |
ReceiveFailure |
Yes |
Receive loss of signal (LOS) |
Major |
LossOfSignal |
Yes |
Receive remote alarm indication (RAI) |
Minor |
ReceiveFailure |
No |
Remote loopback activated |
Minor |
OperationNotification |
No |
Remote loopback requested through DS-3 FEAC (far-end alarm condition) |
Minor |
OperationNotification |
No |
Transmit alarm indication signal (AIS) |
Minor |
AIS |
No |
Transmit loss of frame (LOF) |
Minor |
LossOfFrame |
No |
Transmit remote alarm indication (RAI) |
Minor |
TransmitFailure |
No |
Table 20 lists the supported alarms for E1 channels or ports.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
Port diagnostic failed |
Minor |
ReplaceableUnitProblem |
No |
Port facility loopback enabled |
Minor |
OperationNotification |
No |
Port terminal loopback enabled |
Minor |
OperationNotification |
No |
Receive alarm indication signal (AIS) |
Minor |
AIS |
No |
Receive loss of frame (LOF) |
Major |
LossOfFrame |
Yes |
Receive loss of multi-frame alignment |
Major |
ReceiveFailure |
Yes |
Receive loss of signal (LOS) |
Major |
LossOfSignal |
Yes |
Receive RAI indication |
Minor |
ReceiveFailure |
No |
Table 21 lists the supported alarms for Ethernet ports.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
Excessive collisions detected |
Major |
LinkFailure |
Yes |
Excessive speed 100M detected |
Major |
ConfigurationMismatch |
Yes |
Link down |
Major |
LinkFailure |
Yes |
Over subscription detected |
Major |
ConfigurationMismatch |
Yes |
Port diagnostic failed |
Major |
ReplaceableUnitProblem |
Yes |
Port terminal loopback enabled |
Minor |
OperatorNotification |
No |
Under subscription detected |
Minor |
ConfigurationMismatch |
No |
Table 22 lists the supported alarms for Gigabit Ethernet ports.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
Link down |
Major |
LinkFailure |
Yes |
Link flooded |
Major |
LinkFailure |
Yes |
Port diagnostic failed |
Major |
ReplaceableUnitProblem |
Yes |
Port terminal loopback enabled |
Minor |
OperatorNotification |
No |
Receive loss of signal (LOS) |
Critical |
LossOfSignal |
Yes |
This section provides tables of alarms for the following types of paths on channelized STM-1 and POS traffic cards.
Table 23 lists the supported Virtual Tributary (VT) path alarms.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
VT loss of pointer (LOP-V) |
Major |
LossOfPointer |
Yes |
VT path alarm indication signal (AIS-V) |
Minor |
AIS |
No |
VT path remote failure indication (RFI-V) |
Minor |
FarEndReceiverFailure |
No |
VT payload label mismatch (PLM-V) |
Major |
SignalLabelMismatch |
Yes |
VT unequipped (UNEQ-V) |
Major |
SignalLabelMismatch |
Yes |
Table 24 lists the supported TU-12 path alarms.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
TU-12 (tributary unit-12) alarm indication signal (AIS) |
Minor |
AIS |
No |
TU-12 loss of pointer (LOP) |
Major |
LossOfPointer |
Yes |
VC-12 (virtual container-12) payload label mismatch (PLM) |
Major |
SignalLabelMismatch |
Yes |
VC-12 remote failure indication (RFI) |
Minor |
FarEndReceiverFailure |
No |
VC-12 unequipped (UNEQ) |
Major |
SignalLabelMismatch |
Yes |
Table 25 lists the supported virtual circuit-3 (VC-3) path alarms for the low-order path layer.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
TU-3 (tributary unit-3) alarm indication signal (AIS) |
Minor |
AIS |
No |
TU-3 loss of pointer (LOP) |
Major |
LossOfPointer |
Yes |
VC-3 (virtual container-3) payload label mismatch (PLM) |
Major |
SignalLabelMismatch |
Yes |
VC-3 remote failure indication (RFI) |
Minor |
FarEndReceiverFailure |
No |
VC-3 unequipped (UNEQ) |
Major |
SignalLabelMismatch |
Yes |
Table 26 lists the supported VC-3 path alarms for the high-order path layer.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
AU-3 (administrative unit-3) path alarm indication signal (AIS) |
Minor |
AIS |
No |
VC-3 (virtual container-3) loss of multiframe (LOM) |
Major |
LossOfFrame |
Yes |
VC-3 path trace failure |
Minor |
PathTraceMismatch |
No |
VC-3 path unequipped (UNEQ) |
Major |
SignalLabelMismatch |
Yes |
VC-3 payload label mismatch (PLM) |
Major |
SignalLabelMismatch |
Yes |
VC-3 remote failure indication (RFI) |
Minor |
FarEndReceiverFailure |
No |
Table 27 lists the supported VC-4 path alarms.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
AU-4 (administrative unit-4) path alarm indication signal (AIS) |
Minor |
AIS |
No |
VC-4 (virtual container-4) loss of multiframe (LOM) |
Major |
LossOfFrame |
Yes |
VC-4 path trace failure |
Minor |
PathTraceMismatch |
No |
VC-4 path unequipped (UNEQ) |
Major |
SignalLabelMismatch |
Yes |
VC-4 payload label mismatch (PLM) |
Major |
SignalLabelMismatch |
Yes |
VC-4 remote failure indication (RFI) |
Minor |
FarEndReceiverFailure |
No |
Table 28 lists the supported Synchronous Transport Signal (STS) and Synchronous Transfer Mode (STM) path alarms for the high-order layer.
Description |
Severity |
Probable Cause |
Service Affecting |
---|---|---|---|
ATM loss of cell delineation |
Major |
DegradedSignal |
Yes |
Concatenation mismatch |
Minor |
PayloadTypeMismatch |
No |
Path alarm indication signal (AIS-P) |
Minor |
AIS |
No |
Path loss of pointer (LOP-P) |
Major |
LossOfPointer |
Yes |
Path remote defect indication (RDI-P) |
Minor |
FarEndReceiverFailure |
No |
Path signal degrade (BER [bit error rate]) |
Major |
DegradedSignal |
Yes |
Path signal failure (BER) |
Major |
ExcessiveBER |
Yes |
Path trace failure |
Minor |
PathTraceMismatch |
No |
Path unequipped (UNEQ-P) |
Major |
SignalLabelMismatch |
Yes |
Payload label mismatch (PLM) |
Major |
SignalLabelMismatch |
Yes |